Go Back

Boiler Tube Inspection (EMAT)

Semi-automated system for thickness measurement and Hydrogen Corrosion Cracking (HCC) for boiler tube walls.

Leveraging Innerspec’s years of experience and proprietary technology, FarField NDT uses the TEMATE TG-IS(B) to measure wall loss and detect Hydrogen Corrosion Cracking (HCC) and caustic gauging in boiler tubes.

Features

  • Non-contact EMAT technique.
  • Custom instrumentation and sensors for boiler tube inspection.
  • Permits 100% inspection of boilers instead of spot checking at up to 15cm/s of scanning speed.
  • Ultrasonic EMAT technique provides accurate thickness readings with minimum surface preparation.
  • Only system capable of measuring remaining wall thickness on heavily corroded tubes.
  • Capable of detecting Hydrogen Corrosion Cracking (HCC), pitting, and caustic gouging.
  • Works on carbon steel and cladded tubes.
  • Sensor with integrated encoder and light indicators for fast visual alert to the operator.
  • Exclusive boiler mapping software application permits easy visualization of boiler walls with results of inspection for fast analysis and interpretation.
  • Proven technology with hundreds of boilers and thousands of kilometers of inspected tube worldwide.

‍

‍